Three names that get used interchangeably in quotation emails, and three completely different tests. Here is what a buyer is actually paying for.
The FDA does not approve materials. It publishes regulations, and 21 CFR 177.2600 sets out what a rubber article may release when it contacts food. A supplier claiming “FDA approved” is either simplifying or bluffing. What exists is a compound that passes the extraction limits.
| Standard | Market | What it tests | Validity |
|---|---|---|---|
| FDA 21 CFR 177.2600 | United States | Extractables in distilled water and n-hexane after reflux | Compound + process specific |
| LFGB § 30/31 | Germany / EU | Overall and specific migration, plus a sensory panel | Compound + process specific |
| USP Class VI | Pharma / medical | In vivo and in vitro biocompatibility on the finished material | Material specific |
| ISO 10993-5/-10 | Medical devices | Cytotoxicity, irritation, sensitization | Device and contact-duration specific |
All of these are tied to a specific compound and a specific cure. Change the colour masterbatch, move from peroxide to platinum, or skip post-cure, and the previous report no longer describes the part in the box.
A test report is a statement about a sample at a moment in time. It is not a property of the material in general.
Both are silicone rubber, and on a drawing they look identical. The cure system decides what leaches out of the …
28 Oct 2026 · 7 min read
ID, wall and concentricity are three separate promises. Confusing them is the most common reason a tube that &ld…
21 Oct 2026 · 8 min read
Two tubes, same ID, same wall, 12% different flow rate. The variable was hardness — and it is usually the last t…
07 Oct 2026 · 6 min read
Send a drawing or a sample. We will tell you which compound and hardness we would run, and what it costs at your volume.